TMCnet News

Study Investigates the Impact of Masimo Continuous SpHb® and PVI® on Anesthesia-Related Mortality
[October 22, 2016]

Study Investigates the Impact of Masimo Continuous SpHb® and PVI® on Anesthesia-Related Mortality


Masimo (NASDAQ: MASI) announced today the findings of an abstract presented at the American Society of Anesthesiologists' (ASA) Annual Meeting in Chicago. In the study, researchers at Hôpital Dupuytren, part of the Centre Hospitalier Universitaire of Limoges, France (CHU Limoges), investigated the clinical utility of noninvasive, continuous hemoglobin (SpHb®) and PVI® (a measure of the dynamic changes in perfusion index that occur during the respiratory cycle), two Masimo rainbow SET™ measurements. The researchers' goal was to determine, at the scale of a whole hospital, improvement in mortality and transfusion needs.1

In the prospective, single-center, observational study, Professor Nathalie Nathan and colleagues reviewed two sets of patients over two eleven-month periods, before (2013) and after (2014) implementation of a clinical algorithm to guide transfusion and fluid administration. Anesthesiologists, nurses, and residents were trained on the implementation of the clinical algorithm. Masimo Radical-7® Pulse (News - Alert) CO-Oximeters® were installed in all operating rooms, recovery rooms, and intensive care units. The Radical-7s were connected to Masimo Patient SafetyNet™* for trend data collection. All surgical patients presenting to the hospital were accepted, with these exceptions: EMT, ophthalmology, odontology, radiology, neurosurgery, and patients less than 18 years of age.

The study included 18,867 patients (in the two groups), of whom 3450 underwent SpHb and PVI monitoring via Radical-7. The patients in the monitoring group received vascular filling with crystalloids or blood, according to the clinical algorithm. Demographic, anesthesia, surgical, and transfusion data were collected in electronic medical records. The researchers compared the percentage of patients in the monitored group who received transfusions within the first postoperative 48 hours to the percentage in the non-monitored group. They also compared mortality rates for each group at 30 days and 90 days following surgery.

Using the cox-proportional hazard model, the researchers found that the patients in the group monitored with SpHb and PVI had a 30% reduction in mortality at 30 days and a 25% reduction in mortality at 90 days. The proportion of patients receiving transfusions did not change significantly between the two groups (7.9% in 2013, 8.5% in 2014, p=0.1323), nor did the number of blood units transfused within 48 hours (3.4 ± 2.7 in 2013, 3.4 ± 2.0 in 2014, p>0.05). However, in non-cardiac surgery, patients were transfused sooner in the operative or recovery room (72.9% vs 56.1%, p=0.0002).

The researchers concluded that "Monitoring SpHb and PVI integrated in a vascular filling algorithm allowed earlier transfusion and reduces mortality at a scale of a whole hospital with different clinical practices (and practitioners) and unselected patients."

"Access to continuous monitoring of Hb levels and fluid responsiveness has changed the way we address blood and fluid management. By lowering inadequate fluid filling at the beginning of anesthesia, we are able to avoid diluting patients inadequately and this data helps us to guide precisely the amount of fluids or blood that must be given to patients on a case by case basis," stated Professor Nathan, Head of the Department of Anesthesiology at CHU Limoges. "Patients are transfused earlier when needed and hypovolemia is precisely treated with crystalloid. These two facts may explain the decrease in mortality at one and three months that we observed in this study. We strongly believe that surgeries of intermediate severity such as hip or knee replacement procedures as well as severe surgery will benefit from this technology. Because it is easy to use, quick to administer, provides continuous data, and does not harm the patient in any way, it is more applicable to common clinical practice."

Joe Kiani, Founder and CEO of Masimo, commented, "We have created technologies that have been shwn to save babies' eyesight2, screen for CCHD in newborns3, and reliably monitor patients in post-surgical wards4,5,6, but this is the first time a study has shown that one of our technologies has such a big impact on mortality. Needless to say, we are excited and thank Dr. Nathan for her and her colleagues' research. We look forward to more studies like this that investigate the impact of SpHb and PVI on other patients at other hospitals, and hope to see similar results."



SpHb monitoring may provide additional insight to the directional trend of hemoglobin between invasive blood samplings - when the SpHb trend is stable and the clinician may otherwise think hemoglobin is decreasing; when the SpHb trend is rising and the clinician may otherwise think hemoglobin is not rising fast enough; or when the SpHb trend is decreasing and the clinician may otherwise think hemoglobin is stable. SpHb monitoring, accompanied by laboratory diagnostic testing, may thus help clinicians make more timely and informed decisions, and has been shown to help clinicians provide more timely blood transfusions** and reduce blood transfusions in cases such as neurosurgery and orthopedic surgery.7,8

@MasimoInnovates | #Masimo


*The use of the trademark SafetyNet is under license from University HealthSystem Consortium.

**Clinical decisions regarding red blood cell transfusions should be based on the clinician's judgment considering, among other factors: patient condition, continuous SpHb monitoring, and laboratory diagnostic tests using blood samples.

References

  1. Nathan N et al. Impact of Continuous Perioperative SpHb Monitoring. Proceedings from the 2016 ASA Annual Meeting, Chicago. Abstract #A1103.
  2. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
  3. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;338.
  4. Taenzer AH et al. Impact of Pulse Oximetry Surveillance on Rescue Events and Intensive Care Unit Transfers: A Before-And-After Concurrence Study. Anesthesiology. 2010; 112(2):282-287.
  5. Taenzer AH et al. Postoperative Monitoring - The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
  6. McGrath SP et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety. 2016 Jul;42(7):293-302.
  7. Ehrenfeld JM et al. Continuous Non-invasive Hemoglobin Monitoring during Orthopedia Surgery: A Randomized Trial. J Blood Disorders Transf. 2014. 5:9. 2.
  8. Awada WN et al. Continuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study. J Clin Monit Comput. 2015 Feb 4.

About Masimo

Masimo (NASDAQ: MASI) is a global leader in innovative noninvasive monitoring technologies. Our mission is to improve patient outcomes and reduce the cost of care by taking noninvasive monitoring to new sites and applications. In 1995, the company debuted Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry, which has been shown in multiple studies to significantly reduce false alarms and accurately monitor for true alarms. Masimo SET® is estimated to be used on more than 100 million patients in leading hospitals and other healthcare settings around the world. In 2005, Masimo introduced rainbow® Pulse CO-Oximetry technology, allowing noninvasive and continuous monitoring of blood constituents that previously could only be measured invasively, including total hemoglobin (SpHb®), oxygen content (SpOC™), carboxyhemoglobin (SpCO®), methemoglobin (SpMet®), and more recently, Pleth Variability Index (PVI®) and Oxygen Reserve Index (ORi™), in addition to SpO2, pulse rate, and perfusion index (PI). In 2014, Masimo introduced Root®, an intuitive patient monitoring and connectivity platform with the Masimo Open Connect™ (MOC-9™) interface. Masimo is also taking an active leadership role in mHealth with products such as the Radius-7™ wearable patient monitor and the MightySat™ fingertip pulse oximeter. Additional information about Masimo and its products may be found at www.masimo.com. All published clinical studies on Masimo products can be found at http://www.masimo.com/cpub/clinical-evidence.htm.

Forward-Looking Statements

This press release includes forward-looking statements as defined in Section 27A of the Securities Act of 1933 and Section 21E of the Securities Exchange Act of 1934, in connection with the Private Securities Litigation Reform Act of 1995. These forward-looking statements include, among others, statements regarding the potential effectiveness of Masimo SpHb® and PVI®. These forward-looking statements are based on current expectations about future events affecting us and are subject to risks and uncertainties, all of which are difficult to predict and many of which are beyond our control and could cause our actual results to differ materially and adversely from those expressed in our forward-looking statements as a result of various risk factors, including, but not limited to: risks related to our assumptions regarding the repeatability of clinical results; risks related to our belief that Masimo's unique noninvasive measurement technologies, including Masimo SpHb and PVI, contribute to positive clinical outcomes and patient safety; risks related to our belief that Masimo noninvasive medical breakthroughs provide cost-effective solutions and unique advantages; as well as other factors discussed in the "Risk Factors" section of our most recent reports filed with the Securities and Exchange Commission ("SEC (News - Alert)"), which may be obtained for free at the SEC's website at www.sec.gov. Although we believe that the expectations reflected in our forward-looking statements are reasonable, we do not know whether our expectations will prove correct. All forward-looking statements included in this press release are expressly qualified in their entirety by the foregoing cautionary statements. You are cautioned not to place undue reliance on these forward-looking statements, which speak only as of today's date. We do not undertake any obligation to update, amend or clarify these statements or the "Risk Factors" contained in our most recent reports filed with the SEC, whether as a result of new information, future events or otherwise, except as may be required under the applicable securities laws.